The AVA Envelop features patented Self-Monitoring Automatic Regulating Technology (S.M.A.R.T.) to continuously calculate the patient’s load, movement, and position. Through advanced microprocessing algorithms, it automatically monitors and adjusts internal pressure, ensuring a personalized fit for each patient as if tailor-made.
AVA Envelop is engineered with Deep Breathing Exercise (DBE) and Variable Dynamic Mode (VDM). The DBE function cycles between maximum inflation in the thoracic area and the preset comfort level, helping to expand the chest and improve respiration. The VDM feature offers varied cycle times to promote pressure relief and provide maximum envelopment.
To ensure optimal wound care management, AVA Envelop offers Static and Dynamic therapy modes that deliver effective pressure redistribution and enhance blood circulation. For easy patient transport, the AVA Envelop includes a Transport Mode button that keeps the AVA Envelop mattress inflated even when detached from the power unit.
The IPS Technology, Intelligent Pressure Sensing Technology, works with S.M.A.R.T to create effective envelopment. IPS responds to patient movements on mattress by automatically adjusting internal mattress pressure, which allows AVA Envelop to regulate airflow and continuously provide total envelopment for our patients. Carilex is the first brand in the industry to master IPS. This gives us more experience and vast knowledge in the technology that is years ahead of our competitors.
The AVA Envelop Mattress Replacement System combines intelligent design and comfort. With its modular cell structure, it ensures optimal pressure redistribution and relief, offering patients a truly comfortable and reliable experience.
|
Power Unit model |
SR394 |
|
Power input |
100-240Vac 50/60Hz 0.5-0.3A |
|
Power consumption |
Max. 25W |
|
Weight |
Power Unit: 3.4Kg Mattress: 7kg, 9kg, 10kg, 11kg, 12kg |
|
Dimension |
Power Unit (W x H x D): 13” x 10” x 5” (33.9 x 26.6 x 13cm) Mattress Set (W x L x H): Envelop Lux: 36” x 80” x 7” (90 x 200 x 18cm) FIT: 32” x 80” x 8” (82 x 200 x 20cm) 36” x 80” x 8” (90 x 200 x 20cm) 42” x 80” x 8” (107 x 200 x 20cm) 48” x 80” x 8” (120 x 200 x 20cm) Other size upon request |
|
Agency Approval |
IEC/EN 60601-1 IEC/EN 60601-1-11 IEC/EN 60601-1-2 ANSI/AAMI ES60601-1 |
|
Operating Condition |
Temperature: 5°C to 40°C (41°F to 104°F) Humidity: 15% to 90% |
|
Transportation & Storage Condition |
Temperature: -25°C to 70°C (-13°F to 158°F) Humidity: 0% to 90% |
|
Weight Capacity |
Envelop Lux: 200Kg (440lbs) FIT: 250Kg (550lbs) |
This Power Unit is not AP/APG protected